Exams / EPA Section 608 Technician Certification / 40 CFR §82.157

40 CFR §82.157 — what it says, and how the exam tests it

This section is cited by 10 of our practice questions and is tested on the EPA Section 608 Technician Certification.

The text

§ 82.157 Appliance maintenance and leak repair. (a) Applicability. This section applies as of January 1, 2019. As of April 10, 2020, this section applies only to appliances with a full charge of 50 or more pounds of any class I or class II refrigerant or blend containing a class I or class II refrigerant. Notwithstanding the use of the term refrigerant in this section, the requirements of this section do not apply to appliances containing solely substitute refrigerants. Unless otherwise specified, the requirements of this section apply to the owner or operator of the appliance. (b) Leak rate calculation. Persons adding or removing refrigerant from an appliance must, upon conclusion of that service, provide the owner or operator with documentation that meets the applicable requirements of paragraph (l)(2) of this section. The owner or operator must calculate the leak rate every time refrigerant is added to an appliance unless the addition is made immediately following a retrofit, installation of a new appliance, or qualifies as a seasonal variance. (c) Requirement to address leaks through appliance repair, or retrofitting or retiring an appliance. (1) Owners or operators must repair appliances with a leak rate over the applicable leak rate in this paragraph in accordance with paragraphs (d) through (f) of this section unless the owner or operator elects to retrofit or retire the appliance in compliance with paragraphs (h) and (i) of this section. If the owner or operator elects to repair leaks, but fails to bring the leak rate below the applicable leak rate, the owner or operator must create and implement a retrofit or retirement plan in accordance with paragraphs (h) and (i) of this section. (2) Leak Rates: (i) 20 percent leak rate for commercial refrigeration equipment; (ii) 30 percent leak rate for industrial process refrigeration equipment; and (iii) 10 percent leak rate for comfort cooling appliances or other appliances with a full charge of 50 or more pounds of refrigerant not covered by (c)(2)(i) or (ii) of this section. (d) Appliance repair. Owners or operators must identify and repair leaks in accordance with this paragraph within 30 days (or 120 days if an industrial process shutdown is required) of when refrigerant is added to an appliance exceeding the applicable leak rate in paragraph (c) of this section. (1) A certified technician must conduct…

Public record. Read the full, current section at the official source: www.ecfr.gov

How it comes up on the exam

Practice questions written from this section — answers and explanations are in the drill.

  1. A technician adds refrigerant to a commercial refrigeration appliance that exceeds the applicable leak rate. According to 40 CFR §82.157, within how many days must the owner or operator identify and repair the leaks?
    drill Type II — High-Pressure Appliances →
  2. According to EPA regulations, what is the applicable leak rate that triggers mandatory repair for comfort cooling appliances with a full charge of 50 or more pounds of refrigerant?
    drill Type III — Low-Pressure Appliances →
  3. Under 40 CFR §82.157, what is the applicable leak rate for comfort cooling appliances with a full charge of 50 or more pounds of refrigerant?
    drill Core →