Exams / EPA Section 608 Technician Certification / 40 CFR §82.156
40 CFR §82.156 — what it says, and how the exam tests it
This section is cited by 23 of our practice questions and is tested on the EPA Section 608 Technician Certification.
The text
§ 82.156 Proper evacuation of refrigerant from appliances. Until January 1, 2018, this section applies only to evacuation of refrigerant from appliances containing class I or class II refrigerants. Starting on January 1, 2018, this section applies to evacuation of refrigerant from appliances containing any class I or class II refrigerant or any non-exempt substitute refrigerant, excluding paragraph (i) of this section which applies only to appliances containing class I or class II refrigerants until January 1, 2019. Starting January 1, 2019, the provisions in § 82.157 apply in lieu of paragraph (i) of this section. (a) Appliances (except small appliances, MVACs, and MVAC-like appliances). Before opening appliances (except small appliances, MVACs, and MVAC-like appliances) or disposing of such appliances, technicians must evacuate the refrigerant, including all the liquid refrigerant, to the levels in Table 1 using a recovery and/or recycling machine certified pursuant to § 82.158 unless the situations in paragraphs (a)(1) or (2) of this section apply. Technicians may evacuate either the entire appliance or the part to be serviced, if the refrigerant in the part can be isolated to a system receiver. A technician must verify that the applicable level of evacuation has been reached in the appliance or the part before it is opened. (1) If evacuation of the appliance to the atmosphere is not to be performed after completion of the maintenance, service, or repair, and if the maintenance, service, or repair is not major as defined at § 82.152, the appliance must: (i) Be evacuated to a pressure no higher than 0 psig before it is opened if it is a medium-, high- or very high-pressure appliance; (ii) Be pressurized to a pressure no higher than 0 psig before it is opened if it is a low-pressure appliance. Persons must cover openings when isolation is not possible. Persons pressurizing low-pressure appliances that use refrigerants with boiling points at or below 85 degrees Fahrenheit at 29.9 inches of mercury (standard atmospheric pressure), must not use methods such as nitrogen that require subsequent purging. Persons pressurizing low-pressure appliances that use refrigerants with boiling points above 85 degrees Fahrenheit at 29.9 inches of mercury, must use heat to raise the internal pressure of the appliance as much as possible, but may use nitrogen to raise the…
Public record. Read the full, current section at the official source: www.ecfr.gov
How it comes up on the exam
Practice questions written from this section — answers and explanations are in the drill.
- A technician recovers refrigerant from an appliance being disposed of that has a full charge of 30 pounds. Under 40 CFR §82.156, how long must records of that disposal recovery be kept?
drill Core → - A technician is recovering refrigerant from a small appliance with a functioning compressor using recovery equipment manufactured in 2005. What percentage of the refrigerant must be recovered?
drill Core → - A technician is servicing a medium-pressure appliance with a full charge of 200 pounds or more. Using recovery equipment manufactured before November 15, 1993, to what level must the appliance be evacuated before disposal?
drill Core →